seamless copper tube for air conditioner
1.Product name: Seamless Copper Tube for Air Conditioning
2.Material: TP2(C12200)
3.Chemical composition: Cu-99.90% min, P-0.015 to 0.040%
4.Manufacture:
-The tube shall be manufactured by such hot or cold working processes as to produce a homogeneous uniform
wrought structure in the finished product. The tube shall be cold drawn to the finished size and wall thickness.
-Coil Lengths specified soft annealed temper, shall be bright annealed after coil, then dehydrated, and capped,
plugged, crimped, or otherwise closed at both ends so as to maintain the internal cleanness of the tubing under
nomal conditions of handling and storage.
-Straight lengths specified hard-drawn temper, shall be cleaned and capped, plugged, or otherwise closed at
both ends so as to maintain the internal cleanness of the tubing under normal conditions of handling and storage.
5.Standard Dimensions and Weight, and Tolerance in Diameter and Wall Thickness for Straight Length
Standard Size,in | Outside Diamter,in(mm) | Wall Thickness,in(mm) | Weight,lb/ft(kg/m) | Tolerance | |
Average Outside Diameter,plus and Minus, in(mm) | Wall Thickness, Plus and Minus,in(mm) | ||||
3/8 | 0.375(9.52) | 0.030(0.762) | 0.126(0.187) | 0.001(0.025) | 0.003(0.08) |
1/2 | 0.500(12.7) | 0.035(0.889) | 0.198(0.295) | 0.001(0.025) | 0.004(0.09) |
5/8 | 0.625(15.9) | 0.040(1.02) | 0.285(0.424) | 0.001(0.025) | 0.004(0.10) |
3/4 | 0.750(19.1) | 0.042(1.07) | 0.362(0.539) | 0.001(0.025) | 0.004(0.11) |
7/8 | 0.875(22.3) | 0.045(1.14) | 0.455(0.677) | 0.001(0.025) | 0.004(0.11) |
1 1/8 | 1.125(28.6) | 0.050(1.27) | 0.655(0.975) | 0.0015(0.038) | 0.004(0.13) |
1 3/8 | 1.375(34.9) | 0.055(1.40) | 0.884(1.32) | 0.0015(0.038) | 0.006(0.14) |
1 5/8 | 1.625(41.3) | 0.060(1.52) | 1.14(1.70) | 0.002(0.051) | 0.006(0.15) |
2 1/8 | 2.125(54.0) | 0.070(1.78) | 1.75(2.60) | 0.002(0.051) | 0.007(0.18) |
2 5/8 | 2.625(66.7) | 0.080(2.03) | 2.48(3.69) | 0.002(0.051) | 0.008(0.20) |
3 1/8 | 3.125(19.4) | 0.090(2.29) | 3.33(4.96) | 0.002(0.051) | 0.009(0.23) |
6. Standard Dimensions and Weights, and Tolerances in Diameter and Wall Thickness for Coil Lengths
Standard Size,in. | Outside Diameter,in.(mm) | Wall Thickness,in.(mm) | Weight,lb/ft(kg/m) | Tolerance | |
Average Outside Diameter, plus and Minus, in.(mm) | Wall Thickness, Plus and Minus, in.(mm) | ||||
1/8 | 0.125(3.18) | 0.030(0.762) | 0.0347(0.0516) | 0.002(0.051) | 0.003(0.08) |
3/16 | 0.187(4.75) | 0.030(0.762) | 0.0575(0.0856) | 0.002(0.051) | 0.003(0.08) |
1/4 | 0.250(6.35) | 0.030(0.762) | 0.0804(0.120) | 0.002(0.051) | 0.003(0.08) |
5/16 | 0.312(7.92) | 0.032(0.813) | 0.109(0.162) | 0.002(0.051) | 0.003(0.08) |
3/8 | 0.375(9.52) | 0.032(0.813) | 0.134(0.199) | 0.002(0.051) | 0.003(0.08) |
1/2 | 0.500(12.7) | 0.032(0.813) | 0.182(0.271) | 0.002(0.051) | 0.003(0.08) |
5/8 | 0.625(15.9) | 0.035(0.889) | 0.251(0.373) | 0.002(0.051) | 0.004(0.11) |
3/4 | 0.750(19.1) | 0.035(0.889) | 0.305(0.454) | 0.0025(0.064) | 0.004(0.11) |
3/4 | 0.750(19.1) | 0.042(1.07) | 0.362(0.539) | 0.0025(0.064) | 0.004(0.11) |
7/8 | 0.875(22.3) | 0.045(1.14) | 0.455(0.677) | 0.003(0.076) | 0.004(0.11) |
1 1/8 | 1.125(28.6) | 0.050(1.27) | 0.665(0.975) | 0.0035(0.089) | 0.005(0.13) |
1 3/8 | 1.375(34.9) | 0.055(1.40) | 0.884(1.32) | 0.004(0.10) | 0.006(0.15) |
1 5/8 | 1.625(41.3) | 0.060(1.52) | 1.14(1.70) | 0.0045(0.11) | 0.006(0.15) |
7.Application: For use in the connection, repairs, or alternations of air conditioning or refrigeration units in the field.
8.Picture of copper tube for air conditioner
-straight one
-pancake coil copper tube
9.Packing
straight copper tube-bundled in the plastic bag, then put them in the wood carton.
pancake coil copper tube-packed in the plastic bag, then put them in the cardboard box.
seamless copper tube for air conditioner